Home > Support > Frequently Asked Questions
Frequently Asked Questions
- What is the ESD rating of the PCI products and what methods were followed?
- Human Body Model (HBM): 2000 volts. The method used was JESD-A114-B.
- Is the device package moisture sensitive?
- Yes.
- What is the moisture sensitivity level (1-6) of the products?
- Please contact qa@plxtech.com for questions regarding MSL ratings on a product by product basis.
- What is the safe exposure time after opening the moisture bag?
- 168 hours for Level 3 moisture sensitivity.
- Does the part have to be baked prior to use?
- No. If the part was baked, vacuum sealed and the exposure time did not exceed the 168 hours after opening.
- Does the tray meet the JEDEC standard and is it bakeable?
- The tray meets the JEDEC requirements and is bakeable up to a maximum of 125°C.
- Tray types and respective quantities.
- All production-shipping trays used by PLX Technology are high temperature (125°C) bakeable trays. Furthermore, all tray types
adhere to JEDEC standards. The device count per tray depends on the packaging configuration of the different devices. The
various part counts per tray can be broken down as follows:
| Packaging Technology |
# Parts per Tray |
# Parts per Row |
# Parts per Column |
| 208-pin PQFP |
24 |
8 |
3 |
| 176-pin PQFP |
36 |
9 |
4 |
| 160-pin PQFP |
24 |
8 |
3 |
| 225-ball PBGA |
40 |
10 |
4 |
| 180-ball µBGA |
168 |
21 |
8 |
| 256-ball PBGA |
90 |
15 |
6 |
| 272-ball PBGA |
40 |
10 |
40 |
- What is the Thermal Resistance for the following devices?
| Device |
Thermal Resistance |
| 9030 with 176 QFP package |
30-45 °C/W |
| 9030 with 180 µBGA package |
22-34 °C/W |
| 9050 with 160 QFP package |
30-50 °C/W |
| 9052 with 160 QFP package |
30-50 °C/W |
| 9054 with 176 QFP package |
60-70 °C/W |
| 9054 with 225 BGA package |
60-80 °C/W |
| 9060 series with 208 QFP package |
40-50 °C/W |
| 9080 with 208 QFP package |
30-50 °C/W |
| 9056 with 256 BGA package |
30-40 °C/W |
| 9656 with 272 BGA package |
30-40 °C/W |
- How is the thermal resistance calculated?
- It can be calculated from the ambient temperature Ta, the thermal resistance (Thetaj-a) of the package, and the power consumption PD.
The chip temperature (Tj) = Ta + (PD x Thetaj-a) (°C) where,
Tj = chip junction temperature
Ta = ambient temperature
PD = power consumption
Thetaj-a = thermal resistance
- Are all the parts qualified and are data available?
- All parts have been qualified. Either specific data or "generic" data is available upon request.
- How is the device qualified?
- The product is submitted through various electrical and environmental tests as described in the applicable JEDEC specifications and MIL-STD-883.
- Is generic or product-specific data available?
- Yes, both types of data are available depending on the product.
- How may I obtain generic or product-specific data?
- The data is best obtained via our Sales department or Sales representatives who will notify the Quality Assurance department within
PLX Technology. The data is considered proprietary and has limited distribution for customers who have received approval from the
PLX Sales Department.
- What is the FIT rate for PLX devices?
- The FIT rate for the following products are:
| Device |
FIT Rate |
| PCI 9030 |
30 FITS |
| PCI 9050 |
30 FITS |
| PCI 9052 |
30 FITS |
| PCI 9054 |
30 FITS |
| PCI 9060 (series) |
30 FITS |
| PCI 9080 |
30 FITS |
| PCI 9056 |
40 FITS |
| PCI 9656 |
40 FITS |
- How often are the products qualified, and are there on-going product monitors?
- Once the product is qualified there are subsequent monitors on a periodic basis. This monitor will usually have a subset of tests
derived from the main qualification testing. Should any of those changes occur, re-qualification is required:
- New product release
- Major process change
- Relocation of wafer fabrication or assembly plant
- New equipment
- Change in wafer size
- New process
- What is the Flammability rating of the devices?
- For QFP & BGA packages, the rating is UL94 V-O.
- Are PLX parts Industrial temperature qualified?
- Yes. The following PCI products are qualified from -40°C to +85°C (Ta): PCI 9030, PCI 9050, PCI 9052, PCI 9054, PCI 9080.
- How are QFP leads inspected?
- The leads are inspected using either an optical or laser based lead scanner. The lead scanner inspects the leads for pitch, skew, bent leads,
co-planarity and missing leads. Inspection parameters are taken directly from the product data book.
- What does the part number coding mean?
| field-1 |
field-2 |
- |
field-3 |
field-4 |
field-5 |
field-6 |
| XXX |
XXXX |
- |
XX |
XX |
X |
X |
- Device Class (e.g., PCI9054-AB50PI)
- Part Number (e.g., PCI9054-AB50PI)
- Device Revision (e.g., PCI9054-AB50PI) (Base & Metal Layers)
- Maximum Operating Frequency (in MHz) (e.g., PCI9054-AB50PI)
- Packaging Technology (B=BGA, P=PQFP)
- Operational Temperature Range (I=industrial, C=commercial)
|
- What does the marking mean?
| Line 1 |
PLX Logo |
| Line 2 |
PLX Part Number |
| Line 3 |
Date Codes, ESD Triangle |
| Line 4 |
Lot#, Country of Origin |